Spare Parts

Sl.No. Description Qty.
1 Body 1
2 Sleeve 1
3 Spool 1
4 Capscrew 4
5 End Plug 1
* 6 O' Ring 1
7 Bonded Seal 1
8 Plug Socket Head 1
9 Steel ball 1
* 10 O' Ring 1
11 Spring Pad 1
12 Spring 1
Sl.No. Description Qty.
13 Spring Pad 1
14 Spring 1
15 Spring Casing 1
* 16 O' Ring 1
17 Adjusting Screw 1
18 Top Nut 1
19 Check Nut 1
20 Cap 1
21 Cerclip External 1
* 22 O' Ring 4
23 Spring Dowel 1

Note : * Recommended Spares
While ordering the spares give complete details of Model Code punched on the valve body.

 

Maintenance Manual

MODEL : DPS

Operation and Maintenance Instructions :

Polyhydron make Direct Acting Pressure Sequence valves are reliable hence require very little attention from user. However it is necessary that following points must be kept in mind while storage, operation, commissioning and maintenance.

Storage :

The valve needs to be well lubricated to prevent the spool from getting stuck up in valve body due to possible corrosion. It should be properly covered to protect from dust/dirt.

Operation :

Direct Acting Pressure Sequence valves are designed to cause action to take place in a system in a definite order, and to maintain a predetermined minimum pressure in a primary line while the secondary operation occurs.

Fluid flows freely through the primary passage to operate the first phase until the pressure setting of the valve reached. As the spool moves, flow is diverted to the secondary port to operate a second phase.

To maintain pressure in the primary system, the valve is internally operated. However, the drain connection must be external, since the secondary port is under pressure when valve sequences.

Commissioning :

The things that should be attended to during commissioning are as follows:

The primary line should be connected to the port P of the valve and the secondary to the port A.

For remote controlling (optional) the pilot line is to be connected to the port B.

Tank port must be drained. Cap screws and the corresponding tightening torque should be as mentioned in the data sheet.

Maintenance :

To enhance the proper working of the valve it is necessary to attain the following points. :

The oil must be of prime quality and clean as per ISO code 16/13.

Contaminated oil may lead to the wear of the spool there by increasing clearance between the pilot piston and housing. This results in the improper working of the valve.

The oil temperature must be within the specified range i.e. -20 C to +70 C.

 

All rights reserved.
Subject to revision.

Regd. office & Works :
78-80, Machhe Industrial Estate, Machhe, Belgaum - 590 014. Karnataka, INDIA. 
Phone :
+91-0831-2411001.  Fax : +91-0831-2411002 ,  
E-mail :
 
polyhydron@vsnl.com ,  Website :  www.polyhydron.com

 

Copyright Polyhydron Pvt. Ltd. Belgaum, India.
Site developed by
Polyhydron Pvt. Ltd, Belgaum, India.

Updated on February 04, 2015 03:05 pm .