Description
Double Throttle / Check Valve. Non pressure compensated, Modular construction. Can be used for METER - OUT or METER - IN applications. Interface conforming to
ISO, IS, DIN.
Throttle cum check vavle
Section

Unit Dimensions

Note :
Rotate valve around axis 'X' -'X' by 180 to convert from METER - OUT - CONTROL to METER - IN CONTROL. (Port A & B get interchanged)

Technical Specifications
Construction .........…......... Modular, Spool type, Non-pressure compensated.
Mounting ........................... Modular type, Conforming to IS 10187,
ISO 4401 - AC - 05 - A - A,
DIN 24340.
Mounting position ............. Optional.
Direction of flow ................ For ports P & T Free flow in either direction.
For ports A & B Free flow in one direction.
Adjustable throttled flow in opposite direction
as indicated on the valve dial plate.
Operating pressure ........... 315 bar for all ports.
Viscosity range ................. 10 cSt to 380 cSt.
Fluid temperature range ... -10 C to +80 C.
Flow handling capacity ..... Refer graph.
Mass ................................. 2.4 kg.

 

Performance Curves

Oil used : ISO VG 68, Viscosity : 68 cSt @ 40 C, Temp. @ test : 50 C.

Ordering Informations

Note : Standard valve comes with METER - OUT option.
          To convert to METER - IN refer note in Unit dimensions.

Throttle/Check valve Modular construction TCM
Size 10
Throttle/Check valve facility
Design Code  01

Product Code

 

All rights reserved.
Subject to revision.

Regd. office & Works :
78-80, Machhe Industrial Estate, Machhe, Belgaum - 590 014. Karnataka, INDIA. 
Phone :
+91-0831-2411001.  Fax : +91-0831-2411002 ,  
E-mail :
 
polyhydron@vsnl.com ,  Website :  www.polyhydron.com

 